Leica CV5030 Fully Automated Glass Coverslipper
The Leica CV5030 fully automated glass coverslipper produces slides with superb optical quality for reliable long-term storage.
Its capability of handling a large variety of slide racks from different suppliers makes the Leica CV5030 very flexible. Most common mounting media, including xylene-free varieties, can be used.
The operator can choose between wet or dry coverslipping. The CV5030’s performance achieves three goals: Highly consistent and reliable coverslipping quality, full adaptation to individual laboratory set-ups, integration into staining/coverslipping workstations to form a fully automated, user-friendly operation system.
Features
Leica CV5030 Fully Automated Glass Coverslipper Features
300 coverslips at a rate
Coverslips at a rate of 300 slides per hour using standard microscope slides and glass coverslips of different sizes to increase productivity and efficiency in the lab.
Open system design
Through its open system design, a broad range of mountants can be used for the highest flexibility.
Added flexibility
The CV5030 can be used for different purposes at the same time, e.g. for histology and cytology for added flexibility.
Fume extraction system
The integrated fume extraction system with activated charcoal filter, produces lower concentrations of xylene or xylene substituts in the air, reducing exposure to hazardous fumes for laboratory personnel.
Coverslipper
Specs
Leica CV5030 (New) Fully Automated Glass Coverslipper
Width: | 420 mm (14.27 in) |
Depth: | 600 mm (23.62 in) |
Height: | 550 mm (21.65 in) |
Weight: | 57 kg (125.5 lbs) |
Slide throughput: | 1 slide in 9 seconds |
Volume mounting media bottle: | 250 mL |
Maximum filling volume: | 200 mL |
Relative humidity: | max 80%, non-condensing |
Documents
Documents
Acceptance and Specifications
Leica CV5030 Technical Data DE | (PDF) |
Leica CV5030 Technical Data EN | (PDF) |
Leica CV Ultra comparison Pertex EN | (PDF) |
Brochures
Certificates
EU Declaration Leica CV5030 A en | (PDF) |
Dedicated Articles
pathologypartners | (PDF) |
Installation Requirements
95.10694 Rev A Tech Data Sheet EN | (PDF) |
Material Safety Data Sheets
Newsletters
PathologyPartners 11 2006 | (PDF) |
PathologyPartners 4 | (PDF) |
PathologyPartners 5 | (PDF) |
PathologyPartners 6 | (PDF) |
PathologyPartners 9 2006 | (PDF) |
PathologyPartners 9 | (PDF) |
User Manuals/IFUs
Resources
Configurations
Configurations
Choose your option below, and then use the Contact Us link above to submit a quote request for your selection
Configuration 1 (149CVTS5025)
- Leica CV5030 - Robotic Coverslipper 100-250 VAC / 50-60 Hz - Configuration connected with transfer station TS5025 for use with Leica ST5020 - Multistainer as automated workstation
- High-throughput glass coverslipper, with a speed of 9 seconds per slide.
- Compact bench top unit, requires very little space, works with high-quality standard coverlips in various sizes from 22-24 mm x 40-60 mm.
Configuration 2 (149CVTS5015)
- Leica CV5030 - Robotic Coverslipper 100-250 VAC / 50-60 Hz - Configuration connected with transfer station TS5015 for use with Leica ST5010 Autostainer XL as automated workstation
- High-throughput glass coverslipper, with a speed of 9 seconds per slide.
- Compact bench top unit, requires very little space, works with high-quality standard coverlips in various sizes from 22-24 mm x 40-60 mm.
- Flexibility to run multiple protocols
- Color coded racks reduce errors
- High capacity output drawer
- Intuitive software saves training time
- RFID technology for accurate tracking purposes
- High amount of reagent stations
- Streamlined workflow with slide drying oven
- Precise reagent consumption by single slide counting
- High throughput with 2 robotic arms
- Convenient data import and export
- Prompt service support via RemoteCare